Hydraulic Conductivity Model
K/Ko = (1 - a)3
Vandevivere, et al. 1995
where:
Ko = 0.24 (Io + 0.025 (d50-d10))2 Alyamani and Sen (1993)
a = 2x10-5 pv2 - ((d50-d10)2 / 25) pv